Infra Instruments Chennai proudly presents the Bio Safety Cabinet Class II - Model: IR 811B, designed to provide optimal protection for operators, products, and the environment during microbiological work. With advanced filtration technology and ergonomic design, this cabinet ensures a sterile work environment by maintaining a continuous airflow system and HEPA filtration. The IR 811B is built to meet international safety standards, offering durability, energy efficiency, and ease of use. It’s the ideal solution for research labs, healthcare facilities, and pharmaceutical industries requiring contamination-free operations. Experience reliability and precision with Infra Instruments' cutting-edge solutions.
Description | CLASS II Type A2 | CLASS II Type B2 |
---|---|---|
HEPA Filter Size | 99.97% Efficiency (0.3 Micron) | 99.97% Efficiency (0.3 Micron) |
Pre Filter | 10 Micron | 10 Micron |
Exhaust Filter | 0.3 Micron | 0.3 Micron |
Motor | Statically & Dynamically Balanced | Statically & Dynamically Balanced |
Door | Acrylic Sliding Door | Acrylic Sliding Door |
Gas Supply | Nickel Coated Gas Cock | Nickel Coated Gas Cock |
Cleanliness Level | Class 100 Illumination | Class 100 Illumination |
Switch | 3 Pin Socket – 1 No | 3 Pin Socket – 1 No |
Noise Level | 65 ± 5 db | 65 ± 5 db |
Vibration Level | Less than 2.5 um (0.0001) | Less than 2.5 um (0.0001) |
Power Supply | 230 V AC, 50Hz | 230 V AC, 50Hz |
Light | Fluorescent Light | Fluorescent Light |
Pressure Meter | 0-25 mm i-Tec Magnehelic Gauge | 0-25 mm i-Tec Magnehelic Gauge |
Velocity | 90 ± 10 FPM | 90 ± 10 FPM |
Flow Rotation | 70% Recirculation | 30% Exhaust 100% Exhaust |
Virus Burn Out System | No | Yes |
An AAS is an analytical instrument used to measure the concentration of metal ions in a sample. It works by analyzing the absorption of light by free atoms in a vaporized sample.
AAS instruments are widely used in environmental testing, food safety, pharmaceutical analysis, mining, and metallurgy for accurate metal detection and quantification.
Accessories such as a Graphite Furnace, Auto-Sampler, Hydride Generator, and Hollow-Cathode Lamps are available to enhance performance and functionality.
The detection limits vary depending on the model and configuration. Our AAS systems are designed to detect trace levels of metals with high precision.
Yes, we provide Single and Multi-Element Hollow-Cathode Lamps to support both single-element and multi-element analysis.
Yes, we offer installation, calibration, and comprehensive training services to ensure our customers get the best out of their instruments.